Skip to content Skip to footer

Daikin Air Conditioning FUA71A Under Ceiling Cassette

£3,091.00

Daikin Air Conditioning FUA71A Under Ceiling Cassette 7Kw/24000Btu A+ R32 240V~50Hz
 
Daikin’s Under Ceiling Cassette is a unique product, a 4 way blow system that can be installed under the ceiling in rooms that have solid ceilings or narrow voids that may prevent a traditional cassette being installed. Under Ceiling Cassette Seasonal Smart. The Under Ceiling Cassette exceeds Energy Related Products Directive minimum efficiency standards for Seasonal Efficiency, combining industry leading efficiencies with smart looks and functionality to suit office and retail applications. 

The re-designed profile of the unit means it is less obtrusive when installed. Air discharge louvres close completely when the unit is not operating, adding to the aesthetic. Energy savings can be made using the remote controller which gives control over set-point ranges and day-to-day use of controls. This can give occupants some flexibility over room conditions without compromising energy usage. Energy efficiencies can be improved by utilising the selectable evaporating and condensing temperature option, making the Seasonal Smart Under Ceiling Cassette the ideal solution for energy conscious building managers.

Category: Tags: , , Product ID: 29608

Description

Product Key Feature’s:
• High SCoP
• High Air movement volume
• Fixed wall mounted controller
• Slim construction 
• Pipe runs up to 50 meters
• Low noise levels
• Back-up switch for loss of controller
• Cold draft prevention on heat pump start up
• Fault diagnosis
• Auto re-start after power interruption
• PRE-CHARGED WITH REFRIGERANT for up to 30 metres pipe length

Product Technical Data:
 

Power source 1 ph 240V
Type  Inverter controlled
COOLING (nominal) max. kW 6.5 / 22000 BTU
HEATING (nominal) max. kW 8.0 / 2700BTU
UK Cooling (max) kW  4.5
UK Sensible Cooling kW  4.5
E.E.R. 
Energy label in heating A+
Energy label in cooling  A+
ECA – Yes

INDOOR UNIT :
 

Indoor UnitsSingle Phase
FUA71A
CapacityUK Total Cooling kW7.76
UK Sensible Cooling kW5.32
Nominal Cooling kW6.80
Nominal Heating kW7.50
Seasonal Efficiency (EN14825) COOLINGEnergy LabelA+
Pdesign kW6.80
SEER6.50
Annual Energy Consumption kWh367
Seasonal Efficiency (EN14825) HEATINGEnergy LabelA+
Pdesign kW7.60
SCOP4.20
Annual Energy Consumption kWh2534
Nominal EfficiencyEER / COP4.05 / 4.08
Energy LabelA / A
Annual Energy Consumption kWh840
ir Flow Rate (Cooling) High / Nom / Low m3/sec0.383 / 0.325 /1.933
DimensionsHeight mm198
Width mm950
Depth mm950
Weight kg25
Sound Pressure (Cooling) High / Nom / Low dBA41 / 38 / 35
Sound Power dBA59
ModelRZASG71M2V1
CasingColourIvory white
MaterialPainted galvanized steel plate
DimensionsUnitHeightmm770
Widthmm900
Depthmm320
Packed unitHeightmm900
Widthmm980
Depthmm420
WeightUnitkg60
Packed unitkg64
PackingWeightkg4
Heat exchangerFinTypeWF fin
TreatmentAnti-corrosion treatment (PE)
FanTypePropeller
Discharge directionHorizontal
Quantity1
Air flow rateCoolingNom.m³/min56
HeatingNom.m³/min50
Partialm³/min
Fan motorQuantity1
ModelBrushless DC motor
OutputW94
DriveDirect drive
CompressorQuantity1
TypeHermetically sealed swing compressor
Operation rangeCoolingAmbientMin.°CDB-15
Max.°CDB46
HeatingAmbientMin.°CWB-15
Max.°CWB15.5
Sound power levelCoolingdBA65
HeatingdBA
Sound pressure levelCoolingNom.dBA46
HeatingNom.dBA47
RefrigerantTypeR-32
Chargekg2.45
ChargeTCO2Eq1.65
ControlExpansion valve (electronic type)
GWP675
CircuitsQuantity1
Refrigerant oilTypeFW68DA
Charged volumel0.90
Piping connectionsLiquidQuantity1
TypeFlare connection
ODmm9.52
GasQuantity1
TypeFlare connection
ODmm15.9
DrainQuantity3
TypeHole
ODmm26
Piping lengthOU – IUMin.m5
Max.m50
SystemEquivalentm70
Chargelessm30
Additional refrigerant chargekg/mSee installation manual
Level differenceIU – OUMax.m30.0
IU – IUMax.m0.5
Heat insulationBoth liquid and gas pipes
Defrost methodReversed cycle
Defrost controlSensor for outdoor heat exchanger temperature
Capacity controlMethodInverter controlled
PEDCategoryCategory II
Safety devicesItem01High pressure switch
02Low pressure switch
03Fan driver overload protector
04Fuse
05Compressor motor thermal protector
Standard AccessoriesTie-wraps2
Installation manual1
Refrigerant label for F-gas regulation1
General safety precautions1
LOT10 Energy Label1
Peel off F-gas label1
Power supplyNameV1
Phase1~
FrequencyHz50
VoltageV220-240
Voltage rangeMin.V198
Max.V264
CurrentZmaxListComplies to EN61000-3-11
Minimum Ssc valuekVaEquipment complying with EN / IEC 61000-3-12, See note 2, See note 3
Wiring connectionsFor power supplyRemarkSee installation manual outdoor unit
For connection with indoorRemarkSee installation manual outdoor unit
Power supply intakeSee installation manual outdoor unit
Current – 50HzMaximum fuse amps (MFA)A20
Notes(1) – According to ENER Lot 21
(2) – European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
(3) – Ssc: Short-circuit power
(4) – European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current ≤ 16A per phase.