Description
Key Product Features:
- Heating, cooling, nanoe™ X air purification & de-humidification with simultaneous or independent operation on some modes
- Patrol sensor to detect and eliminate contaminants
- Mild Dry Cooling operation mode for increased comfort and prevention of skin moisture loss
- Maximum efficiency Inverter system, for bigger energy savings A++, A+++
- R32 refrigerant
- Quiet mode(from 19dB)
- Powerful mode
- Uniform dispersion of airflow
- Automatic vertical airflow control
- Hot start mode, increased comfort on heat pump mode, no cool airflow when process starts
- Automatic restart after power cut
- Real time clock with dual ON&OFF timer
- Wi-Fi as standard
- Optional wired weekly timer with 6 settings per day and 42 settings per week
- BMS Connectivity function (indoor unit equipped with PCB port which can be connected to outside network)
- Removable, washable filter
- 15m maximum connection distance
- 15m maximum elevation difference
- Easy Maintenance access
- Self-diagnosis function
Technical Specification:
Cooling capacity Nominal (Min – Max) | kW | 2,05 (0,75 – 2,65) |
EER 1) Nominal (Min – Max) | W/W | 4,66 (4,69 – 4,02) |
SEER 2) | 8,70 A+++ | |
Pdesign (cooling) | kW | 2,1 |
Input power Nominal (Min – Max) | kW | 0,44 (0,16 – 0,66) |
Annual energy consumption 3) | kWh/a | 84 |
Heating capacity Nominal (Min – Max) | kW | 2,80 (0,75 – 4,00) |
Heating capacity at -7 °C | kW | 2,38 |
COP 1) Nominal (Min – Max) | W/W | 4,67 (4,69 – 4,26) |
SCOP 2) | 4,80 A++ | |
Pdesign at -10 °C | kW | 2,4 |
Input power Nominal (Min – Max) | kW | 0,60 (0,16 – 0,94) |
Annual energy consumption 3) | kWh/a | 700 |
Power supply | V | 230 | |
Recommended fuse | A | 16 | |
Connection indoor / outdoor | mm² | 4 x 1,5 | |
Air flow Cool / Heat | m³/min | 10,4 / 11,9 | |
Moisture removal volume | L/h | 1,3 | |
Cool (Hi / Lo / Q-Lo) | dB(A) | 35 / 24 / 19 | |
Heat (Hi / Lo / Q-Lo) | dB(A) | 36 / 25 / 19 | |
Dimension | H x W x D | mm | 295 x 870 x 229 |
Net weight | kg | 10 | |
nanoe X Generator | Mark 3 | ||
Outdoor unit | CU-Z20ZKE | ||
Air flow | Cool / Heat | m³/min | 26,5 / 25,7 |
Sound pressure 4) | Cool / Heat (Hi) | dB(A) | 45 / 46 |
Dimension 5) | H x W x D | mm | 542 x 780 x 289 |
Net weight | kg | 27 | |
Piping diameter | LiquidGas | Inch (mm)Inch (mm) | 1/4 (6,35)3/8 (9,52) |
Pipe length range | m | 3 ~ 15 | |
Elevation difference (in / out) | m | 15 | |
Pre-charged pipe length | m | 7,5 | |
Additional gas amount | g/m | 10 | |
Refrigerant (R32) / CO Eq. kg / T 0,70 / 0,47 | |||
Operating range | Cool Min ~ MaxHeat Min ~ Max | °C°C | -10 ~ +43-20 ~ +24 |
These air conditioning units must be installed by an F-Gas qualified engineer. ( We will ask to view this certificate before the shipment) We can install the unit for you using our F-Gas Certified Engineers.